
Dell EMC VNX Part Number: VNX5200
Product Description: Dell EMC VNX5200 Unified Storage System
All EMC VNX2 models support 2.5 inch and 3.5 inch SAS drives using either the 15-drive DAE, 25-drive DAE, 60-drive DAE, or 120-drive DAE and they also utilize the 6 Gb/s SAS back-end.
Serial Attached SCSI (SAS) drives, Near Line Serial Attached SCSI (NL-SAS) disk drives, and Flash drives are supported.
The EMC VNX2 series offers:
- PCI-E Gen 3 I/O modules
- 6 Gb/s x 4 lanes SAS back-end infrastructure
- Up to x 8 wide (6 Gb/s x 8 lanes) high-bandwidth connection to 60 drive DAE with new 6 Gb SAS I/O module
- Intel Xeon E5 multicore processors
- Expanded UltraFlex I/O, with denser packaging
- NEBS (Network Equipment-Building System) certified DC-powered arrays on the VNX5200, VNX5400, and VNX5600
- Block functionality that supports the FC, iSCSI, and FCoE protocols
- File functionality that supports the NFS, CIFS, and pNFS protocols
- Maximum of up to 1,500 drives
- 120-drive DAE
- Automated tiering with Fully Automated Storage Tiering for Virtual Pools (FAST VP) for block and file data
- Controller based, drive level, Data-At-Rest Encryption
- Updated unified management with Unisphere delivers a cohesive, unified user experience
Install tips:
- Spread flash drives across all available buses, and place them in the lowest numbered enclosures
- Use your flash storage for the active dataset for the best performance
- Plan to reserve at least one of every 30 installed drives of a given type for Hot Sparing. Hot sparing rebuilds the data from a failed drive onto a selected compatible drive. The count can be checked in the GUI at "System->Hot Spare Policy" and at the command line with "naviseccli hotsparepolicy -list"
What drives do you need?
SAS Flash
For extreme performance; these provide the best performance for transactional random workloads, and the lowest write service times. Required for Multicore FAST Cache.
SAS Flash VP
For extreme performance FAST VP tier; these are a higher capacity flash option. Not for use with Multicore FAST Cache.
SAS
For general performance tier.
NL-SAS (generally mechanically the same as 7,200 RPM SATA disks, but feature a SAS interface)
For less active data, well-behaved streaming data, archive purposes, and backups.
EMC VNX Acronyms:
BBU = Battery Backup Units
DAE = Disk Array Enclosures
DME = Data Mover Enclosure
DPE = Disk Processor Enclosure
NEBS = Network Equipment-Building System
SP = Storage Processors
SPE = Storage Processor Enclosure
SPS = Li-Ion Standby Power Supplies
Specs: | Dell EMC VNX 5200 |
Max Raw Capacity | 500.0 TB |
Min/Max Drives | 4/125 |
Max Total Ports per Array | 28 |
Max FC Ports per Array | 24 |
1 GBaseT iSCSI Max Total Ports per Array | 24 |
10 GbE iSCSI Max Total Ports per Array | 12 |
Max FCoE Total Ports per Array | 12 |
Max FAST Cache | 600GB |
Max SAN Hosts | 1,024 |
IO Modules per Array | 6 |
Max Number of Pools | 15 |
Max Number of LUNs (Pool) | 1,000 |
Max Number of LUNs (Classic) | 2,048 |
Protocol | Fibre Channel |
Fibre Channel over Ethernet (FCoE) | |
Network File System (NFS) | |
SMB 3.0 (CIFS) | |
iSCSI | |
Drive Enclosure | 2.5 inch SAS/Flash (2U), 25 drives |
3.5 inch SAS/Flash (3U), 15 drives | |
CPU per Array | 2 x Intel Xeon E5-2600 4-Core 1.2 GHz |
Memory per Array | 32 GB |
Max Total Ports per Array | 28 |
2/4/8 Gb/s FC Max Ports per Array | 24 |
1 GBASE-T iSCSI Max Total Ports per Array | 24 |
Max FCoE Ports Per Array | 12 |
10 GbE iSCSI Max Total Ports per Array | 12 |
RAID Options | 0/1/10/3/5/6 |
Qty of Data Movers | 1-3 |
Data Mover CPU | Intel Xeon 5600 |
Data Mover RAM | 6 GB |
IO Modules per Data Mover | 3 |
Max FC Ports per Data Mover | 4 |
Max IP Ports per Data Mover | 8 |
Max 1 GBaseT Ports per Data Mover | 8 |
Max 10 GbE Ports per Data Mover | 4 |
Standby Power | 1 Battery per storage processor |
Primarily For | Mid-Range Storage |
Storage Consolidation |
When you purchase EMC VNX storage arrays and other EMC hardware from Maximum Midrange, you join other clients such as Boeing, NASA, Northrop Grumman, and hospitals and universities throughout the United States, Canada and the world.
We have a history of client satisfaction and return customers.
Give us a call for references 855-932-6627.